Drain Grade & Pipe Slope Calculator — NZ

Calculate pipe gradient, fall, and minimum grade for drainage pipes to NZ plumbing code requirements.

NZ Drainage Pipe Grade Requirements

All drainage systems in NZ must comply with AS/NZS 3500 (Plumbing and Drainage) as adopted by the NZ Building Code.

Minimum Grades by Pipe Size

Pipe diameter Minimum grade Minimum fall/m
40–50mm (basin, shower) 1:40 25mm/m
65–80mm 1:60 16.7mm/m
100mm (main drain) 1:80 12.5mm/m
150mm (sewer) 1:150 6.7mm/m

Why Grade Matters

  • Too flat → solids settle, blockages, odours
  • Too steep → water outruns solids (self-siphonage), trap seal loss
  • Sweet spot for 100mm: 1:60 to 1:80

Fixture Units (NZ AS/NZS 3500)

Fixture Fixture units
Hand basin 1
Shower 2
Bath 2
WC 4
Kitchen sink 2
Dishwasher 2

All drainage work must be done by a licensed drainlayer.